Condo & strata acoustic approval kit

Make your flooring
approval easier.

Compare Dura floor systems, review IIC and STC results, and prepare a clear submission for your condo board or strata council.

Assembly-specific documentation   •   Acoustic expertise since 1957

Choose your flooring assembly

Compare systems by finished floor.

Browse single or multi resilient layer systems, then review the assembly and its IIC and STC results.

IIC and STC apply to the complete tested floor-ceiling assembly. Confirm concrete thickness, ceiling configuration, finished-floor thickness and installation conditions in the original report. Layer illustrations are not to scale.

01 · Multi resilient layer

Multi resilient layer floor systems

Two resilient membranes separated by a topping. Membrane #1 is the lower layer; membrane #2 is the upper layer.

Engineered hardwood / laminate

2 assemblies
System M01

Dura-Son 3.5 mm / Dura-Son MB 3.5 mm

IIC74Impact sound
STC64Airborne sound
Finished flooringFloating or glued engineered hardwood / laminate
Resilient membrane #2Dura-Son 3.5 mm or Dura-Son MB 3.5 mm
ToppingWood (Plywood 2 × ⅜″)
Resilient membrane #1Super Dura 10 mm
SubfloorConcrete

Dura-Son MB: floating installations. Confirm the applicable product and installation method in the original report.

System M02

Dura-Son MB 3.5 mm

IIC74Impact sound
STC64Airborne sound
Finished flooringFloating engineered hardwood / laminate
Resilient membrane #2Dura-Son MB 3.5 mm
ToppingWood (Plywood 2 × ⅜″)
Resilient membrane #1Super Dura 10 mm
SubfloorConcrete

Carpet

3 assemblies
System M03

Duracushion 6 mm

IIC94Impact sound
STC64Airborne sound
Finished flooringCarpet
Resilient membrane #2Duracushion 6 mm
ToppingWood (Plywood 2 × ⅜″)
Resilient membrane #1Super Dura 10 mm
SubfloorConcrete
System M04

Duracoustic 8 mm

IIC89Impact sound
STC64Airborne sound
Finished flooringCarpet
Resilient membrane #2Duracoustic 8 mm
ToppingCement (Cement Board 2 × ½″)
Resilient membrane #1Duracoustic 8 mm
SubfloorConcrete
System M05

Super Dura 10 mm

IIC94Impact sound
STC64Airborne sound
Finished flooringCarpet
Resilient membrane #2Super Dura 10 mm
ToppingWood (Plywood 2 × ⅜″)
Resilient membrane #1Super Dura 10 mm
SubfloorConcrete

Vinyl

1 assembly

Ceramic

1 assembly
System M07

Duraquiet 3 mm

IIC72Impact sound
STC64Airborne sound
Finished flooringCeramic
Resilient membrane #2Duraquiet 3 mm
ToppingWood (Plywood 2 × ⅜″)
Resilient membrane #1Super Dura 10 mm
SubfloorConcrete

02 · Single resilient layer

Single resilient layer floor systems

One resilient membrane in the floor system. Choose your finished flooring below.

Engineered hardwood / laminate

2 assemblies
System S01

Dura-Son 3.5 mm / Dura-Son MB 3.5 mm

IIC69Impact sound
STC63Airborne sound
Finished flooringFloating or glued engineered hardwood / laminate
Resilient membraneDura-Son 3.5 mm or Dura-Son MB 3.5 mm
SubfloorConcrete

Dura-Son MB: floating installations. Confirm the applicable product and installation method in the original report.

Carpet

4 assemblies

Vinyl

2 assemblies

Ceramic

1 assembly

Carpet tile

1 assembly

A ready-to-edit template

Your condo-board cover letter.

Download the template, fill in your property and flooring details, and attach the relevant supporting documents.

Edit in Word or a compatible editor. Send the completed letter to your board or property manager.

Flooring renovation submission

To the condo board / strata council

Property: [Building name and address]
Unit: [Unit number]

Proposed flooring • Dura underlayment
Building construction • Supporting test report

Please review the attached proposal and advise whether further information is required.

Acoustic ratings, briefly.

IIC · Impact sound

Laboratory impact sound rating for a complete floor-ceiling assembly, including noise from footsteps and dropped objects.

STC · Airborne sound

Airborne sound rating of a complete tested assembly, including transmission of speech and other airborne noise.

AIIC / FIIC

Impact ratings measured in an actual building. Use the designation stated in the report.

ΔIIC

Impact insulation improvement relative to a reference bare concrete slab under specified test conditions.

Need help choosing a report?

Send Dura your proposed flooring and your condo’s acoustic requirements. We can help identify relevant available documentation.

Contact Us
Important: Test results apply only to the assemblies and conditions described in the original reports. Laboratory performance does not guarantee field results or condo/strata approval. Confirm project requirements and obtain required approval before installation.